ALT calibration procedure

ALT’s tuning can be sensitive to temperature changes.

if you have time, wait 30 minutes after turning it on so it warms up.

if you are in a hurry, you can use the detune mode (see manual) to adjust the tuning for each oscillator.

if ALT is still out of tune after 30 minutes (without having changed the detune settings), you can try to re-calibrate ALT (every unit has been calibrated by us during assembly).

steps described here must be followed precisely:

Tonic note calibration (no CV)

  1. ALT is turned off

  2. maintain Notes clicked, turned on ALT and flip the tonic / scale switch - a LED animation should pop up - release Notes

  3. click on Notes once - LED C# should appear

  4. turn off ALT

  5. turn on ALT - root note should be ok now

1V / octave CV tracking calibration

ALT should be able to track 1V / octave correctly on 4 to 5 octaves range.

if it’s not, the calibration can be revised:

  1. ALT is turned off

  2. maintain Notes clicked, turned on ALT and flip the tonic / scale switch - a LED animation should pop up - release Notes

  3. click on Notes once - LED C# should appear

  4. plug in CV pitch a reliable -3V DC voltage source, carefull, accuracy of the voltage send will determine the accuracy of your tracking - click on Notes - LED D# should appear

  5. change voltage source to -1V DC - click on Notes - LED E# should appear

  6. change voltage source to +1V DC - click on Notes - LED F# should appear

  7. change voltage source to +3V DC - click on Notes - LED G# should appear

  8. ALT should restart - yu can unplug your voltage source - new calibration has bee saved

if needed, please contact us on the support forum section of our discord server.